: Sensor input error. Check for broken sensor wires or reverse polarity on Terminals 9 and 10.
: K, J, E, S, N, T, B, Wre (Thermocouple); PT100, CU50 (RTD) Accuracy : ±0.5% of full scale Resolution : 1°C or 0.1°C Control Output : Relay (3A) or SSR (Voltage pulse, 12V DC) Power Supply : 85–265V AC, 50/60 Hz Dimensions : 48mm x 48mm x 85mm (1/16 DIN) Wiring and Connections
Correct wiring is critical for safe operation. Always disconnect power before making connections. Refer to the specific diagram on your unit's label for the most accurate pinouts.
If you are looking to or integration using this controller, could you tell me: sinotimer mc101 manual
: Available in 12V, 24V, 110V, and 220V versions [3, 5].
Connect A to Pin 9, B to Pin 10, and B to Pin 11. 3. Operating the Controller (Key Functions)
The Sinotimer MC101 series consists of high-precision, intelligent digital temperature controllers. They are widely used in industrial automation, plastics machinery, food processing, and laboratory equipment. This comprehensive manual covers everything you need to install, wire, program, and troubleshoot your MC101 controller. 1. Technical Specifications and Dimensions : Sensor input error
When in settings mode, use the button to cycle through parameters and arrow keys to change values. Description SL Sensor Type Set input type (e.g., K, E, P+100). rE Control Mode Set to P (PID) or O-F (On/Off). P Proportional Band Determines the strength of the PID control. I Integral Time Removes steady-state error. d Derivative Time Predicts system behavior to reduce overshoot. dF Differential (Hysteresis) Used in On/Off mode (O-F). oL Output Limit Maximum output power (0–100%). AL1 Alarm 1 Value Sets the trigger point for the alarm. C-F Unit Selection Set to C (Celsius) or F (Fahrenheit). 5. Setting Up PID vs. On/Off Control A. PID Control (For Precise Temperature)
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
Note: To exit the setup menu at any time, hold the button down again for 3 seconds, or wait 30 seconds for the device to automatically time out. 6. Utilizing the Auto-Tuning Feature Always disconnect power before making connections
: The upper red LED display shows your live measured temperature or active parameter abbreviations during menu indexing.
The controller will now cycle the heater on and off 2 to 3 times to calculate the thermal mass.
: Over-range error. The measured temperature exceeds the sensor's maximum limits.
Shows the Set Value (your target temperature) or parameter codes.