Right-click the node and select Activate Server . If successful, the icon will turn green. Troubleshooting and Technical Support
Installation is just the first step. To connect to your PLC, you must configure the driver. Here is a simplified configuration walkthrough.
Simplified configuration to reduce manual intervention.
I'll now open some of the more promising results to gather detailed information. I'll also perform some follow-up searches as outlined in the plan. search results have provided a wealth of information. The PDF from knowledge.insourcess.com provides installation and configuration details for DASABCIP 5.0. The PDF from cdn.logic-control.com provides a tech note on configuring the DAS ABCIP server. The Chinese forum post provides a step-by-step guide in Chinese. The CSDN page provides a guide in Chinese. The troubleshooting pages provide details on using WWClient, resolving configuration errors, troubleshooting port communication, and forcing a tag database reload. The PLCTalk thread discusses Windows 10 compatibility. Another tech note provides steps to resolve configuration editor issues. The search results from AVEVA and PLCTalk provide additional context.
Downloading and installing the Wonderware DASABCIP driver is the standard approach for establishing robust, high-performance communication between AVEVA software and Allen-Bradley PLCs. By accessing the , you can ensure you have the latest, most secure version for your industrial automation needs.
Once installed, configuring the driver is crucial for successful communication. 1. Open the SMC (System Management Console) Open the ArchestrA SMC from the Start Menu.
| | Supported Models / Types | Communication Object in DAServer | | :--------------------------------- | :----------------------------------------------------------------------------------------------------------------------- | :-------------------------------------------------- | | ControlLogix | 1756-L1, -L55, -L61, -L63, L7x series with Ethernet modules (e.g., 1756-ENBT/A, 1756-EN2T) | ENB_CLX (for Ethernet modules) or CPLX (for CPU with embedded Ethernet) | | CompactLogix | 1769-L23, -L32E, -L35E (embedded Ethernet), 1769-L16ER, -L24ER, -L33ER, -L36ERM | ENB_CPLX | | GuardLogix | 1756-L7xS, -L6xS safety controllers | ENB_CLX (treated as a ControlLogix) | | MicroLogix | 1100, 1400 (embedded Ethernet) | ML_EN | | FlexLogix | 1794-L34 with Ethernet modules (1788-ENBT) | ENB_FLX | | Legacy PLCs | PLC-5E, SLC 5/05 (with Ethernet modules) | ENB_CLX / DHRIO_CLX (for DH+ communication) | | SoftLogix 5800 | Software-based controller | ENB_CLX |
: After installation, open the System Management Console (SMC) .
: After rebooting, open the ArchestrA System Management Console (SMC) . You can find this in your Windows Start Menu under the Wonderware or AVEVA folder. In the SMC, expand the "DAServer Manager" and look for the ArchestrA.DASABCIP.1 object. If you see it, the installation was successful.